Suggestions For Drainpipe Layout Of Sewage Hoist

We have recently made a survey on the layout of water pipes, and our professional technicians will give you answers to some questions:

1. The horizontal pipe of the sewage hoist must have a minimum downward inclination of 1:100;

2. If the sewage elevator is to install a vertical drain pipe, it must be arranged before the horizontal pipe;

3. It is recommended to install drain plug at the bottom of vertical pipe to ensure that the pipe is empty during maintenance;

4. If the layout of the sewage elevator pipeline is obviously lower than the position of the equipment, it is recommended to install an exhaust valve at the first point of the pipeline to avoid siphon effect.

5. The drainage pipe of the sewage hoist must be connected to the main drainage equipment with standard pipe fittings;

6. Ensure that all external pipes of the sewage hoist are properly protected and sealed to avoid frost.